Liquid-Cooled Construction
Liquid cooling supports thermal integration with the host system. Request coolant, flow, temperature and connection requirements for the selected configuration.
The CTS3460-M15 Series integrates a liquid-cooled on-board charger and DC-DC converter in one assembly, delivering up to 3.0kW OBC and 1.8kW 14V auxiliary power. Features include active PFC, fully digital control, CAN communication, bootloader support, and IP67 design support. Four configurations available.
CTS3460-M15 Series · Liquid-Cooled 2-in-1 Assembly
Battery charging and 14V auxiliary power in one integrated assembly.
The CTS3460-M15 Series combines an on-board charger and a DC-DC converter with 90–290VAC input. Four configurations provide model-dependent charging power up to 3.0kW and DC-DC output up to 1.8kW, with CAN communication and software parameter adjustment.
Product Overview
The CTS3460-M15 integrates high-voltage battery charging and low-voltage DC-DC conversion in one liquid-cooled assembly. The OBC charges the high-voltage battery, while the DC-DC section provides 14V power for auxiliary electrical systems.
The design incorporates circuit-board potting, independently mounted magnetic components and fully digital control. CAN communication, bootloader support and software parameter adjustment assist commissioning and maintenance.
Select the configuration that matches your battery voltage range and auxiliary load. Confirm cooling and interface requirements during technical review.
Product Features
Liquid cooling supports thermal integration with the host system. Request coolant, flow, temperature and connection requirements for the selected configuration.
Circuit-board potting and independently mounted magnetic components form part of the assembly’s mechanical and electrical construction.
A modular power design, fully digital control and active power factor correction support operation with 90–290VAC input.
Protection at both hardware and software levels supports operation within the specified application conditions.
CAN communication and bootloader functionality assist integration and firmware maintenance. Supporting software enables parameter adjustment.
The specification describes support for an IP67 assembly design. Confirm final protection, connector sealing and installation requirements for the supplied configuration.
Technical Specifications
All listed models specify 90–290VAC input. OBC power, DC-DC rating and high-voltage output range depend on the selected model.
| Model | AC Input | OBC Power | HV Output | HV Output Range | DC-DC Power | LV Output |
|---|---|---|---|---|---|---|
| CTS3462-M15-XX | 90–290VAC | 3.0kW | 360V / 10A | 250–450VDC | 1.8kW | 14V / 128A |
| CTS3463-M15-XX | 90–290VAC | 1.5kW | 144V / 22A | 100–180VDC | 1.8kW | 14V / 128A |
| CTS3464-M15-XX | 90–290VAC | 1.5kW | 108V / 30A | 80–140VDC | 1.8kW | 14V / 128A |
| CTS3465-M15-XX | 90–290VAC | 1.5kW | 72V / 45A | 50–100VDC | 1.2kW | 14V / 85A |
Values are reproduced from the supplied specification. Listed voltage, current and power values should not be assumed to be simultaneously available. Confirm charging power, current limits, cooling conditions and permitted simultaneous operation with CTS before final selection.
Frequently Asked Questions
Share your battery specifications, auxiliary loads and cooling-system requirements for technical review.
Contact Technical Sales →It combines a liquid-cooled on-board charger and a DC-DC converter in one assembly, providing high-voltage battery charging and 14V auxiliary output.
The supplied table lists 3.0kW for CTS3462-M15-XX and 1.5kW for CTS3463-M15-XX, CTS3464-M15-XX and CTS3465-M15-XX.
CTS3462-M15-XX, CTS3463-M15-XX and CTS3464-M15-XX list 1.8kW at 14V/128A. CTS3465-M15-XX lists 1.2kW at 14V/85A.
Ask CTS for the coolant specification, flow rate, inlet temperature range, pressure limits and connection details for the selected configuration.
Yes. The specification lists CAN communication, bootloader support and software parameter adjustment. Request protocol documentation to assess compatibility with your system.
The specification describes support for IP67 assembly design. Confirm final protection, connector sealing and installation requirements with CTS.
Start Your Project
Looking for a liquid-cooled on-board charger with integrated DC-DC conversion? Send your application details for model selection, technical documentation and a quotation.