Liquid-Cooled Construction
Liquid cooling supports thermal integration with the host system. Confirm coolant, flow, temperature and connection requirements with CTS during project review.
The CTS3410-M15 Series integrates a liquid-cooled 6.6kW on-board charger with a 2.5kW DC-DC converter, delivering high-voltage battery charging and 14V/178A auxiliary power in one compact assembly. Featuring ≥93% efficiency, active PFC, CAN communication, bootloader support, and six model-specific output ranges, it supports flexible EV and battery-powered equipment integration.
CTS3410-M15 Series · Liquid-Cooled 2-in-1 Assembly
High-voltage battery charging and 14V auxiliary power in one integrated assembly.
The CTS3410-M15 Series combines a 6.6kW on-board charger with a 2.5kW DC-DC converter. Featuring 90–290VAC input, six model-specific high-voltage output ranges and a listed 14V/178A auxiliary output, it supports power-system integration for electric vehicles and battery-powered equipment.
Product Overview
The CTS3410-M15 integrates a high-voltage on-board charger and a low-voltage DC-DC converter within one liquid-cooled assembly. The OBC charges the battery, while the DC-DC section provides 14V auxiliary output for low-voltage electrical systems.
The construction incorporates circuit-board potting and independently mounted magnetic components. Fully digital control, CAN communication, bootloader support and software parameter adjustment assist integration and maintenance.
Select the high-voltage output range that matches your battery requirements, then confirm cooling and interface details during technical review.
Product Features
Liquid cooling supports thermal integration with the host system. Confirm coolant, flow, temperature and connection requirements with CTS during project review.
Circuit-board potting and independently mounted magnetic components form part of the assembly’s mechanical and electrical construction.
A modular power design, fully digital control and active power factor correction support operation with 90–290VAC input.
Protection at both hardware and software levels supports operation within the specified application conditions.
CAN communication and bootloader functionality assist system integration and firmware maintenance. Supporting software enables parameter adjustment.
The specification describes support for an IP67 assembly design. Confirm the final protection rating, connector sealing and installation requirements for your configuration.
Technical Specifications
All listed models feature 90–290VAC input, 6.6kW OBC power and 2.5kW DC-DC output at 14V/178A.
| Model | AC Input | OBC Power | HV Output | HV Output Range | DC-DC Power | LV Output |
|---|---|---|---|---|---|---|
| CTS3411-M15-XX | 90–290VAC | 6.6kW | 720V / 9A | 500–900VDC | 2.5kW | 14V / 178A |
| CTS3412-M15-XX | 90–290VAC | 6.6kW | 540V / 12A | 400–750VDC | 2.5kW | 14V / 178A |
| CTS3413-M15-XX | 90–290VAC | 6.6kW | 360V / 18A | 250–500VDC | 2.5kW | 14V / 178A |
| CTS3414-M15-XX | 90–290VAC | 6.6kW | 144V / 44A | 100–180VDC | 2.5kW | 14V / 178A |
| CTS3415-M15-XX | 90–290VAC | 6.6kW | 108V / 60A | 80–140VDC | 2.5kW | 14V / 178A |
| CTS3416-M15-XX | 90–290VAC | 6.6kW | 80V / 80A | 50–110VDC | 2.5kW | 14V / 178A |
Values are reproduced from the supplied specification. Confirm available power, current limits, cooling conditions and permitted simultaneous operation for your application before final selection.
Frequently Asked Questions
Share your battery specifications, auxiliary loads and cooling-system conditions for technical review.
Contact Technical Sales →It combines a liquid-cooled 6.6kW on-board charger and a 2.5kW DC-DC converter in one assembly, providing high-voltage battery charging and 14V auxiliary output.
All listed models specify 90–290VAC input. Confirm available charging power under your intended supply conditions with CTS.
Six model-specific ranges are listed: 500–900VDC, 400–750VDC, 250–500VDC, 100–180VDC, 80–140VDC and 50–110VDC.
Yes. The supplied specification lists 2.5kW DC-DC power and 14V/178A output for all six models.
Ask CTS for the required coolant specification, flow rate, inlet temperature range, pressure limits and connection details for the selected configuration.
Yes. The specification lists CAN communication, bootloader support and software parameter adjustment. Request interface documentation to assess compatibility with your system.
The specification describes support for IP67 assembly design. Confirm final protection, connector sealing and installation requirements with CTS.
Start Your Project
Looking for a liquid-cooled 6.6kW on-board charger with integrated DC-DC conversion? Send your application details for model selection, technical documentation and a quotation.
sarah@ctscharger.comOpens your email app with an inquiry draft.